batches/liq live 2
Audit

IBU-L-0008

Ready for Closure🧪 Liquid

Ibuprofen Oral Suspension 100mg/5mL · Line 5 · 8,000 bottles

Container: Amber Glass Bottle 60mL
Batch Size: 8,000 bottles
Line: Line 5 · Liquid Manufacturing Suite
pH Target: 4 (spec: 3–5)
Fill Volume: 60mL (±1mL)
Viscosity: 420cP (spec: 380–460)
Batch Formula Ref: BF-IBU-2026-0008
Water System Ref: PW-2026-06-04
🧪 Compounding→🔬 Filtration→💧 Filling→🔒 Sealing→📦 Packing
Theoretical yield
8k
Actual
8k
Yield %
97.3%
🔐 SHA-256:computing…
Sealed 06 Jun 2026, 21:30 IST · ✅ Verified
In-process checks
#StageModeParameterValueSpecStatusOperatorTimestampReviewed By
1CompoundingSteady StatepH3.9 pH3–5 pHPassPriya Sharma6/4/2026, 5:00:00 AM✅ Rajesh Kumar
2CompoundingSteady StatepH4.1 pH3–5 pHPassPriya Sharma6/4/2026, 6:30:00 AM✅ Rajesh Kumar
3CompoundingSteady StateViscosity415 cP380–460 cPPassPriya Sharma6/4/2026, 7:00:00 AM✅ Rajesh Kumar
4CompoundingSteady StateClarity1 visual1–1 visualPassPriya Sharma6/4/2026, 8:00:00 AM✅ Rajesh Kumar
5CompoundingSteady StatepH4 pH3–5 pHPassPriya Sharma6/4/2026, 9:30:00 AM✅ Rajesh Kumar
6FiltrationSteady StateFilter Integrity Test1 visual1–1 visualPassRohan Mehta6/4/2026, 12:00:00 PM✅ Rajesh Kumar
7FiltrationSteady StateTurbidity0.8 NTU0–2 NTUPassRohan Mehta6/4/2026, 12:30:00 PM✅ Rajesh Kumar
8FiltrationSteady StatepH (post-filter)4 pH3–5 pHPassRohan Mehta6/4/2026, 1:00:00 PM✅ Rajesh Kumar
9FillingInitial ModeFill Volume60.1 mL59–61 mLPassSanjay Khanna6/5/2026, 2:00:00 AM✅ Rajesh Kumar
10FillingInitial ModeFill Volume59.8 mL59–61 mLPassSanjay Khanna6/5/2026, 3:30:00 AM✅ Rajesh Kumar
11FillingRun ModeFill Volume60.2 mL59–61 mLPassSanjay Khanna6/5/2026, 5:00:00 AM✅ Rajesh Kumar
12FillingRun ModeAppearance1 visual1–1 visualPassSanjay Khanna6/5/2026, 6:00:00 AM✅ Rajesh Kumar
13SealingSteady StateTorque Test18 N·cm15–25 N·cmPassSanjay Khanna6/5/2026, 8:00:00 AM✅ Rajesh Kumar
14SealingSteady StateContainer Closure Integrity1 visual1–1 visualPassSanjay Khanna6/5/2026, 9:00:00 AM✅ Rajesh Kumar
15PackingSteady StatePrint Verification1 visual1–1 visualPassSanjay Khanna6/6/2026, 2:00:00 AM✅ Rajesh Kumar
16PackingSteady StateBottle Count per Shipper12 bottles12–12 bottlesPassSanjay Khanna6/6/2026, 3:00:00 AM✅ Rajesh Kumar
Audit trail (this batch)
  • Batch started6/4/2026, 4:00:00 AM
  • Check #1 recorded — pH 3.9pH (PASS)Priya Sharma · 6/4/2026, 5:00:00 AM
  • Check #2 recorded — pH 4.1pH (PASS)Priya Sharma · 6/4/2026, 6:30:00 AM
  • Check #3 recorded — Viscosity 415cP (PASS)Priya Sharma · 6/4/2026, 7:00:00 AM
  • Check #4 recorded — Clarity 1visual (PASS)Priya Sharma · 6/4/2026, 8:00:00 AM
  • Check #5 recorded — pH 4pH (PASS)Priya Sharma · 6/4/2026, 9:30:00 AM
  • Check #6 recorded — Filter Integrity Test 1visual (PASS)Rohan Mehta · 6/4/2026, 12:00:00 PM
  • Check #7 recorded — Turbidity 0.8NTU (PASS)Rohan Mehta · 6/4/2026, 12:30:00 PM
  • Check #8 recorded — pH (post-filter) 4pH (PASS)Rohan Mehta · 6/4/2026, 1:00:00 PM
  • Check #9 recorded — Fill Volume 60.1mL (PASS)Sanjay Khanna · 6/5/2026, 2:00:00 AM
  • Check #10 recorded — Fill Volume 59.8mL (PASS)Sanjay Khanna · 6/5/2026, 3:30:00 AM
  • Check #11 recorded — Fill Volume 60.2mL (PASS)Sanjay Khanna · 6/5/2026, 5:00:00 AM
  • Check #12 recorded — Appearance 1visual (PASS)Sanjay Khanna · 6/5/2026, 6:00:00 AM
  • Check #13 recorded — Torque Test 18N·cm (PASS)Sanjay Khanna · 6/5/2026, 8:00:00 AM
  • Check #14 recorded — Container Closure Integrity 1visual (PASS)Sanjay Khanna · 6/5/2026, 9:00:00 AM
  • Check #15 recorded — Print Verification 1visual (PASS)Sanjay Khanna · 6/6/2026, 2:00:00 AM
  • Check #16 recorded — Bottle Count per Shipper 12bottles (PASS)Sanjay Khanna · 6/6/2026, 3:00:00 AM
🔍 Audit Readiness: 71/100 (CDSCO)
Last inspection: 15 Mar 2026 | Next: 05 Aug 2026
Open Audit Mode →