Stratogene Pharma
capa
Today
Active
3
Ready
2
Open Dev.
1
Yield 30d
95.8%
OOS 30d
0.11%
CAPAs
Corrective and Preventive Actions linked to closed deviations.
All CAPAs (3)
| CAPA ID | Deviation | Root Cause | Owner | Target | Status |
|---|---|---|---|---|---|
| CAPA-MET-0891-001 | DEV-MET-0891-002 | Compression force drift due to 16-day calibration interval. Machine A pressure reduced from target 20 kN causing underfill. | vikram.singh | 2026-06-07 | IN PROGRESS |
| CAPA-MET-0843-001 | DEV-MET-0843-001 | Machine A calibration drift — load cell out of tolerance after 28 days. | vikram.singh | 2026-04-10 | CLOSED |